ClinicalDocument/participant(s) MAY be present. When present, this element SHALL be in accordance with the HL7 CDA R2 standard with a time element and further constrained by this specification to require the presence of name, addr and telecom. In particular, when the ordering provider of the order (or group of orders) fulfilled by this laboratory report is present in the CDA, it
SHALL be documented as a participant with the attribute typeCode valued “REF” (referrer). Additionally, the ordering provider SHALL have the following:
<templateId root="1.3.6.1.4.1.19376.1.3.3.1.6"/> - The templateId element identifies this participant as an ordering physician. The templateId SHALL have root="1.3.6.1.4.1.19376.1.3.3.1.6".
Kontext
Elternknoten des Template-Element mit Id 1.3.6.1.4.1.19376.1.3.3.1.6
Klassifikation
CDA Header Level Template
Offen/Geschlossen
Offen (auch andere als die definierten Elemente sind erlaubt)
Benutzt von / Benutzt
Benutzt von 0 Transactions und 0 Templates, Benutzt 2 Templates
In particular, when the ordering provider of the order (or group of orders) fulfilled by this laboratory report is present in the CDA, it SHALL be documented as a participant with the attribute typeCode valued “REF” (referrer).
hl7:templateId
II
1 … 1
M
The templateId element identifies this participant as an ordering physician. The templateId SHALL have root="1.3.6.1.4.1.19376.1.3.3.1.6".
()
@root
uid
1 … 1
F
1.3.6.1.4.1.19376.1.3.3.1.6
hl7:associatedEntity
1 … 1
R
()
hl7:addr
AD
1 … *
R
ClinicalDocument/participant(s) MAY be present. When present, this element SHALL be in accordance with the HL7 CDA R2 standard with a time element and further constrained by this specification to require the presence of addr.
()
hl7:telecom
TEL
1 … *
R
ClinicalDocument/participant(s) MAY be present. When present, this element SHALL be in accordance with the HL7 CDA R2 standard with a time element and further constrained by this specification to require the presence of telecom.
()
hl7:associatedPerson
0 … 1
ClinicalDocument/participant(s) MAY be present. When present, this element SHALL be in accordance with the HL7 CDA R2 standard with a time element and further constrained by this specification to require the presence of name.
()
Eingefügt
von 1.2.40.0.34.11.90001 PersonElements (DYNAMIC)
@classCode
0 … 1
F
PSN
@determinerCode
0 … 1
F
INSTANCE
hl7:name
PN
1 … 1
()
hl7:scopingOrganization
0 … 1
All persons (including the patient) and organizations mentioned in the document SHALL provide elements name, addr and telecom.
()
Eingefügt
von 1.2.40.0.34.11.90002 OrganizationElements (DYNAMIC)