5.399
Bearbeitungen
Änderungen
→Spezifikation
=====Spezifikation=====
======Referenzbereich (observation/referenceRange)======
{| class="wikitable" width="100%"
|-
! colspan="5" style="text-align:left" width="20%" | Element/Attribut ||style="text-align:left" width="5%" | DT ||style="text-align:left" width="5%" | Kard ||style="text-align:left" width="5%" | Konf ||style="text-align:left" width="65%" | Beschreibung
|- style="background:#FFFFFF"
| colspan="5" style="text-align:left" | referenceRange|| POCD_MT000040.ReferenceRange|| 0..1 || O ||
|- style="background:#FFFFFF"
| || colspan="4" | @typeCode|| cs|| 1..1 || M || Fester Wert: '''REFV'''
|- style="background:#FFFFFF"
| ||colspan="4" | observationRange|| POCD_MT000040.ReferenceRange|| 1..1 || M ||
|- style="background:#FFFFFF"
| || || colspan="3" |@classCode|| cs|| 1..1 || M || Fester Wert: '''OBS'''
|- style="background:#FFFFFF"
| || || colspan="3" |@moodCode|| cs|| 1..1 || M || Fester Wert: '''EVN.CRT'''
|- style="background:#FFFFFF"
| || || colspan="3" |text|| ED|| 1..1 || M|| Referenz auf den Referenzbereich im Narrativen Text
|- style="background:#FFFFFF"
| || || || colspan="2" |reference|| || 1..1 || M||
|- style="background:#FFFFFF"
| || || || || @value|| || 1..1 || M||Referenz auf Referenzbereich im narrativen Block (vgl. 4.2.9.2)
|- style="background:#FFFFFF"
| || || colspan="3" |value|| PQ, IVL_PQ, INT, IVL_INT, RTO, RTO_QTY_QTY, RTO_PQ_PQ|| 0..1 || O|| Wert des Kriteriums
|- style="background:#FFFFFF"
| || || colspan="3" |interpretationCode|| CE CNE|| 1..1 || M|| Fester Wert: N<br/>Analog zu Kapitel 4.4.7.3.8 mit der Einschränkung code=“N“
|}
======Werte des Referenzbereichs (referenceRange/value)======
{| class="wikitable" width="100%"
|-
! colspan="3" style="text-align:left" width="20%" | Element/Attribut ||style="text-align:left" width="5%" | DT ||style="text-align:left" width="5%" | Kard ||style="text-align:left" width="5%" | Konf ||style="text-align:left" width="65%" | Beschreibung
|- style="background:#FFFFFF"
| colspan="3" style="text-align:left" | value||IVL_PQ|| 0..1 || O ||
|- style="background:#FFFFFF"
| || colspan="2" | @xsi:type|| cs|| 1..1 || M || Fester Wert: '''IVL_PQ''' (für physical quantity)
|- style="background:#FFFFFF"
| ||colspan="2" | low|| PQ || 1..1 ||R || Unterer Grenzwert<br/>Zugelassene nullFlavor: <br/>'''NINF''' (negativ unendlich), <br/>'''NA''' (nicht anwendbar)
|- style="background:#FFFFFF"
| || || @value|| cs|| 1..1 || M || Wert des unteren Grenzwerts
|- style="background:#FFFFFF"
| || || @unit|| cs|| 1..1 || M || Physikalische Einheit des unteren Grenzwerts (MUSS ident der Einheit des oberen Grenzwertes sein)
|- style="background:#FFFFFF"
| || || @inclusive|| BL|| 0..1 || O|| Offene oder abgeschlossene Intervallgrenze
|- style="background:#FFFFFF"
| ||colspan="2" | high|| PQ || 1..1 ||R || Oberer Grenzwert<br/>Zugelassene nullFlavor: <br/>'''PINF''' (positiv unendlich), <br/>'''NA''' (nicht anwendbar)
|- style="background:#FFFFFF"
| || || @value|| cs|| 1..1 || M || Wert des oberen Grenzwerts
|- style="background:#FFFFFF"
| || || @unit|| cs|| 1..1 || M || Physikalische Einheit des oberen Grenzwerts (MUSS ident der Einheit des unteren Grenzwertes sein)
|- style="background:#FFFFFF"
| || || @inclusive|| BL|| 0..1 || O|| Offene oder abgeschlossene Intervallgrenze
|}
====Externes Labor====